At first glance, liquid cooling looks simple. Liquid is pumped through a cooler, it absorbs heat, and it's cooled back down with a radiator. But because you're working with liquid, the design principles become more complicated.

  1. Dan 2 termometer air raksa. Hasil pengujian karakteristik Mini Cooling Tower menunjukan penurunan pada suhu (range), approach dan efektivitas sebesar 8oC, 2oC dan 80%. Hasil analisis COD air limbah yang direfluks menggunakan air kran, Mini Cooling Tower, dan bak penampung berturut-turut yaitu 6400 mg/L, 6266.7 mg/L, dan.
  2. Cooling Tower is a kind of heat exchanger. The difference lies in the method of energy transfer. Cooling tower may also be considered as a Mass Transfer device because the cooling of water takes place because due to the evaporation of water caused.
  3. Namun ternyata sistem liquid cooling pun terdapat di hape loh. Sistem Liquid cooling sendiri adalah sistem yang mendingkan hape mu dengan liquid (cairan). Sistem liquid cooling sendiri sudah digunakan beberapa hape loh. Nah, berikut ini 3 hape yang menggunakan sistem liquid cooling.

Water Conducts Electricity

Water cooling is considered by many to be a viable option when it comes to keeping the CPU cool. Check out our handy guide to getting started with using liquid to prevent overheating. Liquid cooling Allowed cooling agents Drinking water; Water-glycol mixture Temperature of cooling agent 0-43 °C (I )(input); 43-55 °C please see manual for further details Temperature rise during circula-tion max. No condensation allowed System max. Working pressure 6 bar/30 bar peak Cooling agent fl ow rates 25 L/min; fl ow requirements.

Obviously, you don't want the system to leak. This is a more common concern to those new to liquid cooling. In actuality, it's a rare occurance.

Hose clamps used internally are a precaution in Koolance systems. Each device is designed to fit snugly with the next, and although not recommended, systems generally run fine without being clamped. Anyone who has installed a Koolance system quickly realizes the amount of sheer physical stress a typical hose connection can withstand.

LiquidCoolingPerbedaan Water Cooling Dan Liquid Cooling

Koolance components are also pressure-tested at many times their operating rate during the manufacturing process. For example, air is injected into the radiator at 70 times (7kg/cm2, 100psi) the normal running pressure to certify it from leakage.

Koolance user manuals provide instructions on testing each cooling system prior to placing any hardware into the chassis. This allows customers to validate the work they have done on nozzles and tubing arrangement before operating the computer.

Pump Reliability

The pump is a liquid cooling system's 'heart'. In conformance with that analogy, a similar effect can happen to the system if this component were to fail. This doesn't mean it is necessary for a liquid cooling system to use a $200 pump. It only means you can not use any off-the-shelf aquarium pump and hope it continues to operate for months and years under computer cooling conditions.

Different pumps are used in Koolance systems, depending on the thermal application. All models are specifically tested for long-term use, with reliability generally exceeding 30k-50k hours MTBF (3.4 to 5.7 years of continuous 24/7 operation).

Fail-Safes

Let's assume something does go wrong. A motherboard cooler was installed, but the tubing got folded during installation of a new video card. There is almost no liquid flow, which is similar to the effect of a dead pump. The CPU is heating up, the liquid is absorbing the additional heat, but slowly, the liquid temperature begins to increase.

Perbedaan Water Cooling Dan Liquid Cooling Unit

With a regular liquid cooling kit, this situation could result in a dead computer. Koolance systems, however, have built-in hardware safety features. Once your liquid temperature reaches a configured level (for example, 50°C/122°F), an alarm sounds. If you're not there to hear or see it, the system can shut off power to the computer automatically.

Dan

Corrosion

There are multiple types of chemical reactions that can be present in a cooling system that uses liquid. The most common is galvanic corrosion, caused by different metals in an electrolyte (in this situation, water). These varying electrode potentials can create a 'battery' effect, damaging the anode metal.

Using domestic tap water can encourage corrosion. Tap water contains numerous trace elements that can accelerate this process. This is the reason distilled water should be used (not 'purified', 'de-ionized', or bottled drinking water). Koolance's liquid coolant features many additives combined with water: anti-corrosives, anti-biology, and other chemicals that are commonly used in the engineering field to help avoid reactions. Koolance coolant is renowned for its extended time between replacement (2-3 years).